EXAM FIRE-INSPECTOR-II BIBLE & FIRE-INSPECTOR-II EXAM SIMULATOR

Exam Fire-Inspector-II Bible & Fire-Inspector-II Exam Simulator

Exam Fire-Inspector-II Bible & Fire-Inspector-II Exam Simulator

Blog Article

Tags: Exam Fire-Inspector-II Bible, Fire-Inspector-II Exam Simulator, New Fire-Inspector-II Test Practice, Authorized Fire-Inspector-II Exam Dumps, Reliable Fire-Inspector-II Real Exam

After years of operation, our platform has accumulated a wide network of relationships, so that we were able to learn about the changes in the exam at the first time. This is a benefit that students who have not purchased Fire-Inspector-II exam guide can't get. The team of experts hired by 67 - Fire Inspector II Exam study questions constantly updates and supplements the contents of study materials according to the latest syllabus and the latest industry research results. We also have dedicated staff to maintain Fire-Inspector-II Exam Material every day, and you can be sure that compared to other test materials on the market, 67 - Fire Inspector II Exam study questions are the most advanced.

Our Fire-Inspector-II test questions provide free trial services for all customers so that you can better understand our products. You can experience the effects of outside products in advance by downloading clue versions of our Fire-Inspector-II exam torrent. In addition, it has simple procedure to buy our learning materials. After your payment is successful, you will receive an e-mail from our company within 10 minutes. After you click on the link and log in, you can start learning using our Fire-Inspector-II test material. You can download our Fire-Inspector-II test questions at any time.

>> Exam Fire-Inspector-II Bible <<

100% Pass Useful International Code Council - Fire-Inspector-II - Exam 67 - Fire Inspector II Exam Bible

We can make sure that if you purchase our Fire-Inspector-II exam questions, you will have the right to enjoy our perfect after sale service and the high quality products. So do not hesitate and buy our Fire-Inspector-II study guide, we believe you will find surprise from our exam products. And not only you can enjoy the service before you pay for our Fire-Inspector-II learning guide, you can also have the right to have free updates for one year after your purchase.

International Code Council 67 - Fire Inspector II Exam Sample Questions (Q81-Q86):

NEW QUESTION # 81
In the fire code, ABS plastics are designated as ___ plastic materials.

  • A. Commodity Class III
  • B. Group C
  • C. Group A
  • D. Group B

Answer: C

Explanation:
IFC Section 2303.7 classifies ABS (acrylonitrile butadiene styrene) plastics as Group A (high-hazard) due to their flammability and smoke production, per NFPA 13. Options B and C are less hazardous, D is a commodity class, not a plastic group. Thus, A is correct.


NEW QUESTION # 82
Refrigeration units or systems having a refrigerant circuit containing Group A1 refrigerant shall be provided with approved emergency signs, charts, and labels in accordance with NFPA 704 when the quantity exceeds
___ lb.

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: B

Explanation:
Refrigeration systems and units are regulated under IFC 2021, Section 605 - Refrigeration Equipment, and the requirement for emergency signs, charts, and labels is tied to the NFPA 704 Hazardous Materials Identification System.
IFC 2021, Section 605.12.3 - Signage for Refrigeration Systems:
States that approved emergency signs, charts, and labels must be provided when the refrigerant quantity exceeds 220 pounds for Group A1 refrigerants.
Definition of Group A1 Refrigerants (Low Toxicity, Low Flammability):
Examples include R-134a, R-410A, and R-22, which are commonly used in commercial and industrial HVAC systems.
Why Other Options Are Incorrect?
A: 30 lb. - Too low; labeling requirements do not apply at this threshold.
B: 100 lb. - Incorrect; the IFC requirement specifies 220 lb.
C: 200 lb. - Close, but still below the 220 lb. threshold.


NEW QUESTION # 83
Panic hardware is required on exit doors serving an occupant load of __ or more in a Group __ Occupancy

  • A. 50; A
  • B. 10; A
  • C. 50; M
  • D. 100; F

Answer: A

Explanation:
The requirement for panic hardware on exit doors is specified in 2021 IFC Section 1010.2.9 - Panic and Fire Exit Hardware.
IFC Section 1010.2.9.1 - Where Panic Hardware is Required:
Panic hardware is required for Group A (Assembly) occupancies when the occupant load is 50 or more.
It is also required in certain Group E (Educational) and Group R-1 (Hotels and Dormitories) occupancies under specific conditions.
Why Other Options Are Incorrect?
A: 10; A - The threshold for panic hardware in Group A occupancies is 50, not 10.
C: 50; M - Group M (Mercantile) does not require panic hardware unless specifically required by another section of the code.
D: 100; F - Panic hardware is not required in Group F (Factory) occupancies at 100 occupants; the threshold applies primarily to Group A.


NEW QUESTION # 84
Newly upholstered furniture may be required to resist ignition by cigarettes in common areas in which of the following nonsprinklered occupancies?

  • A. Group I-2
  • B. Group A-1
  • C. Office spaces
  • D. Libraries in Group E

Answer: A

Explanation:
In nonsprinklered occupancies, newly upholstered furniture in common areas must resist ignition by cigarettes primarily in Group I-2 occupancies (such as hospitals, nursing homes, and care facilities). This requirement reduces the risk of fire ignition in environments where occupants may have limited mobility and are unable to evacuate quickly.
Reference to Fire Inspector Documentation:
1. 2021 International Fire Code (IFC) - Section 805.2 (Ignition Resistance of Upholstered Furniture and Mattresses) IFC 805.2 specifies that nonsprinklered Group I-2 occupancies must have upholstered furniture that resists ignition by cigarettes because these settings involve vulnerable populations who may need assistance in an emergency.
2. NFPA 101 - Life Safety Code (2021 Edition) - Section 10.3.2 (Fire-Retardant Upholstered Furniture) NFPA 101, Section 10.3.2 aligns with the IFC in requiring that furniture in health care facilities (Group I-2) must meet fire resistance standards to prevent ignition from cigarettes and other sources.
Detailed Explanation of Answer Choices:
Option A (Correct): Group I-2 (hospitals, nursing homes, and assisted living facilities) is required to have cigarette-ignition-resistant upholstered furniture in nonsprinklered common areas.
Option B (Incorrect): Group A-1 (theaters and performing arts venues) does not have this requirement, as seating arrangements are different and typically involve fire-resistant materials.
Option C (Incorrect): Office spaces (Business Occupancies, Group B) do not require ignition-resistant furniture under fire code regulations.
Option D (Incorrect): Libraries in Group E (Educational Occupancies) are not required to have this furniture unless otherwise specified by local codes.
Thus, the correct and verified answer is: A. Group I-2


NEW QUESTION # 85
Given: A nonsprinklered commercial Type II-B building has a fire flow requirement of 7,000 gpm. If a sprinkler system is installed throughout the building, the new required fire flow is at least ___ gpm. (Assume that the new required fire flow is sufficient to meet the requirements of the sprinkler system.)

  • A. 1,500
  • B. 2,250
  • C. 1,750
  • D. 2,000

Answer: A

Explanation:
IFC Section 903.3.5 and Appendix B (Fire-Flow Requirements) allow a reduction in fire flow when sprinklers are installed. For a Type II-B building (noncombustible, unprotected), the base fire flow (7,000 gpm) reflects a large, unsprinklered structure (e.g., per Table B105.1(2)). With full sprinkler protection, IFC B105.2 permits a reduction to as low as 25% of the original flow or the sprinkler demand (whichever is greater), typically
1,500 gpm for commercial buildings per NFPA 13 standards, assuming adequate water supply. Options B, C, and D exceed this minimum without justification. Thus, A is correct.


NEW QUESTION # 86
......

Our Fire-Inspector-II test guides have a higher standard of practice and are rich in content. If you are anxious about how to get Fire-Inspector-II certification, considering purchasing our Fire-Inspector-II study tool is a wise choice and you will not feel regretted. Our learning materials will successfully promote your acquisition of certification. Our Fire-Inspector-II qualification test closely follow changes in the exam outline and practice. In order to provide effective help to customers, on the one hand, the problems of our Fire-Inspector-II test guides are designed fitting to the latest and basic knowledge. For difficult knowledge, we will use examples and chart to help you learn better. On the other hand, our Fire-Inspector-II test guides also focus on key knowledge and points that are difficult to understand to help customers better absorb knowledge. Only when you personally experience our Fire-Inspector-II qualification test can you better feel the benefits of our products. Join us soon.

Fire-Inspector-II Exam Simulator: https://www.passcollection.com/Fire-Inspector-II_real-exams.html

In order to provide the best after sale service to our customers, our company has always used the strictest standards when recruiting the employees of after-sale service (about Fire-Inspector-II exam questions), in other words, all of our after-sale service staffs are carefully chosen, I can assure you that all of our after-sale service staffs will be patient & professional when you have any question or problem about Fire-Inspector-II test preparation, we will make our best endeavors to provide after sale service for you, International Code Council Exam Fire-Inspector-II Bible We are confident that your future goals will begin with this successful exam.

Virtual Machine Files, Sally Hass, Employee Benefits Life Planning Manager, Weyerhaeuser Company, In order to provide the best after sale service to our customers, our company has always used the strictest standards when recruiting the employees of after-sale service (about Fire-Inspector-II Exam Questions), in other words, all of our after-sale service staffs are carefully chosen, I can assure you that all of our after-sale service staffs will be patient & professional when you have any question or problem about Fire-Inspector-II test preparation, we will make our best endeavors to provide after sale service for you.

Quiz International Code Council - Fire-Inspector-II –The Best Exam Bible

We are confident that your future goals will begin with this successful exam, While Fire-Inspector-II practice quiz give you a 99% pass rate, you really only need to spend very little time.

Here you can find all kinds of Fire-Inspector-II exam questions with the most accurate answers and explanations, PassCollections Fire-Inspector-II International Code Council audio lectures and PassCollection Fire-Inspector-II audio study guide can really get cleared with ease.

Report this page